The OPG — Operations, Property & Governance All articles
Operations

When the Alarm Is Only a Test: Board Evidence for Fire Evacuation Across Several Premises

The OPG — Operations, Property & Governance
When the Alarm Is Only a Test: Board Evidence for Fire Evacuation Across Several Premises

Photo: Tilman2007, CC BY-SA 4.0, via Wikimedia Commons

For an SME with one office, a fire evacuation drill can easily become a line in a diary and a signature on a sheet. Across several premises, the same duty becomes a governance question. The board is not expected to sound the alarm or count people at the assembly point. It is expected to know that someone competent has done so, that the arrangements are tested, and that weaknesses are corrected before they matter.

The legal framework is familiar. The Regulatory Reform (Fire Safety) Order 2005 places duties on the responsible person for non-domestic premises in England and Wales. Equivalent regimes apply in Scotland and Northern Ireland. The Equality Act 2010 adds a practical obligation to make reasonable adjustments for people who cannot use a standard escape route. A drill record is one of the clearest ways to show that both duties are being managed in practice.

Start with the responsible person’s map

Before asking for drill records, the board should establish who is responsible for fire safety at each site. In a multi-let building, that may be shared with a landlord or managing agent. In an owner-occupied unit, it usually sits with the company. The register should name the responsible person, the competent persons who support them, the assembly point, the roll-call method and the owner of any personal emergency evacuation plan (PEEP).

This map matters because drill evidence is often weakest at the edges: a small satellite office, a warehouse unit, a serviced office suite or a site where the landlord controls the common parts. The board pack should show those edges, not just the head office.

What a drill record should prove

A useful record answers four questions: what was tested, who took part, what happened and what changed. At minimum, capture the date and time, the site, the scenario, whether the drill was planned or unannounced, the person leading it, the number of staff, visitors and contractors involved, the roll-call result, the time taken to evacuate and any issues raised.

Where a PEEP was activated, record that it was tested without putting unnecessary medical detail into the board pack. A simple note that the plan was exercised and reviewed is usually enough. The record should also distinguish a full evacuation drill from a weekly alarm test. They are not the same evidence, and insurers and enforcing authorities know the difference.

Frequency and triggers

There is no single statutory interval that fits every premises. The fire risk assessment should set the drill frequency, and many organisations adopt at least an annual full evacuation for each site. That baseline should be adjusted for shift patterns, building alterations, new equipment, changes to escape routes, contractor works, new PEEPs and any near miss or false alarm that revealed confusion.

For a multi-site estate, stagger the schedule rather than running every drill in the same week. That gives the board a rolling view of performance and avoids the temptation to treat the exercise as a corporate event rather than a site-level test. Occasional unannounced drills can be useful, but they should be proportionate and safe.

PEEPs are living documents

A PEEP is not a form to be completed at induction and filed away. It should be reviewed when a person changes role, moves desk, changes working hours or adopts a new aid or routine. The board does not need to see the personal details, but it should see whether PEEPs are in place, whether they have been reviewed and whether they have been practised.

Where a site has no current PEEP, that may be because no one needs one. The record should say so, rather than leaving a blank space that looks like an oversight.

The board pack: a one-page heat map

A single-page summary is usually more useful than a folder of certificates. For each site, show the date of the last drill, the date of the next due drill, the number of PEEPs and their review status, any open actions and a red, amber or green rating. Red should mean overdue or a material failure. Amber should mean an action is open but the site remains broadly safe. Green should mean tested and closed.

The minutes should record the board’s challenge, not just its receipt of the paper. A useful question is: what did we learn, and what has changed since the last drill? If the answer is nothing, the board should ask whether the exercise was meaningful.

When the insurer or authority asks

Keep a pre-agreed evidence pack that can be retrieved within 48 hours. It should include the fire risk assessment, the drill schedule and records, PEEP summaries, maintenance records for alarms and extinguishers, training records and the responsible person’s appointment. If there is a gap, disclose it with a remediation plan. Do not create retrospective records. A dated action plan is credible; a reconstructed drill sheet is not.

The board’s aim is not to turn evacuation into a paperwork ritual. It is to know, with evidence, that the alarm is more than a test and that every site can be emptied safely.

All Articles

Related Articles

The Tenant’s Opening File: Ten Records to Secure at Lease Commencement

The Tenant’s Opening File: Ten Records to Secure at Lease Commencement

The Neighbour’s Builder and Your Board: A Decision Path for Party Wall Notices

The Neighbour’s Builder and Your Board: A Decision Path for Party Wall Notices

The Accessibility File: A Board's Working Record of Barriers, Duties and Adjustments